How to Shut Off a Water Heater in an Emergency

A step-by-step emergency shutdown for a water heater, covering the water valve, the supply at the meter or well, gas, propane and electricity.

An emergency shutdown is three decisions in a fixed order: stop the water, stop the heat, then decide what to do about what is already wet. Doing them in the other order lets the water keep running while you look for a valve.

Step one: stop the water

If the leak is at the heater, close the valve on the cold inlet pipe above the tank. It is the closest shutoff and it isolates the unit from the house.

If the valve will not turn, or the leak is elsewhere, close the supply. On a municipal connection that is the meter box at the property line, which usually has a customer valve beside the meter. On a well property it is the valve at the pressure tank, and if the water keeps coming, the pump's breaker.

A well keeps refilling a house until the pump stops. That is why the breaker is part of the sequence and not an afterthought.

Step two: stop the heat

Gas, piped. Close the appliance valve on the supply line to the heater. Leave the meter alone unless there is a smell of gas in the building, in which case the meter valve closes and the utility is called.

Gas, propane. Close the valve on the tank outdoors. The regulator and pigtail downstream stay pressurised, so treat that section as live until it is isolated and tested.

Electric. Switch the circuit off at the panel. This comes first if the tank may have drained, because an element energised without water fails within seconds.

Step three: deal with what is wet

Water near a panel, a socket or an extension lead is an electrical hazard: kill the circuit before touching anything wet near wiring, and do not stand in water to reach a breaker.

Water that has travelled into a wall, a ceiling or a floor needs drying before any decision about the heater. A wet cavity that is closed up and left is a mould problem with a delay.

If the water is heading somewhere it should not, such as a neighbour's property or a lower floor, diverting what is already flowing with soil or a barrier can help once the supply is off.

What not to do

Do not relight a unit whose burner compartment has been wet. Do not seal a leaking seam with tape or compound. Do not hold a relief valve open as a way to stop a drip, because it will not reseat reliably and the cause remains.

And do not hunt for a gas leak indoors. If you can smell gas, leave, avoid switches, and call the utility or the fire department from outside.

Immediately after

Once the flow has stopped, the fault sorts into two: a tank whose shell has failed, which means replacement, or a component that gave way, which is a repair. The replacement hub and the repair hub cover both, and the emergency hub has the wider version of this sequence including what to say when you call.

Be ready before the emergency

Find the three shutoffs now, while nothing is leaking: the valve above the tank, the supply at the meter or the pressure tank, and the gas valve or the tank in the yard. Photograph them on a phone.

Two minutes of looking now is worth an hour of searching in a wet hallway, and on a well property it is worth knowing where the pump breaker sits before you need it. A location page such as Hasley Canyon's emergency page shows why that matters on a property with its own supply.

Questions about this article

What is the first thing to shut off?

The water at the heater if the leak is at the unit, otherwise the supply at the meter or the well. Then the heat source. Water first limits the damage; fuel second limits the hazard.

Where is the valve on the heater?

On the cold inlet pipe above the tank, usually a gate or ball valve within arm's reach. Turning it clockwise closes it. If it is seized, go to the supply rather than forcing it.

Where is the supply shutoff?

On a municipal connection, a meter box at the property line, sometimes with a customer valve beside it. On a well, the valve at the pressure tank and the pump breaker.

What if the relief valve is the thing that is leaking?

Close the fuel or the power first, then the water if it does not stop. A relief valve passing continuously is relieving pressure or has failed, and leaving it running while the burner heats the tank makes it worse.