In the valley, an installation is judged by how it looks and how it tests. Here it is judged by the first hard freeze: what was protected, what was not, and whether anyone thought about the pipe that runs along the north wall.
Start with the room, not the unit
The placement conversation comes first, because it decides everything after it.
An interior utility room or closet is the easy case: freeze exposure is limited to the runs that leave the room, and those can be insulated.
A garage is the common compromise. It stays warmer than outside but not reliably above freezing, so piping insulation matters and a gas unit's ignition still has to be raised above the floor.
A crawl space or outbuilding is where installations fail. The unit can run perfectly for months and then lose its feed line on the first hard night, because nothing in that space is kept above freezing. Protection there is a design decision — pipe insulation, a heat source the manual allows, or a documented drain-down at the end of the season — and the manual decides which is permitted.
The permit and what it covers
The county's Building and Safety Division permits the job, with the application and the inspection both handled in EPIC-LA. What the inspector checks is the code's list: strapping, expansion control, relief discharge, venting and combustion air, plus the garage clearance rule for gas.
The relief discharge is the item that deserves the most thought here. It has to fall continuously and end somewhere that cannot ice over and block it.
Sizing on a groundwater supply
Demand is the household's; the water is the mountain's. A house here peaks at a full table on a holiday rather than on a hot afternoon, so recovery matters more than a large volume. Groundwater leaves scale, so a tank with a full-port drain is easier to keep clear, and the flush interval is worth setting on day one rather than after the first rumble.
Long runs to a far bathroom or an outbuilding are better solved with a second small unit than with a bigger tank, where the layout allows. The tankless page covers the wall-hung alternative and its winter caveat.
Venting above the snow line
A gas unit's flue has to terminate clear of the roof and clear of the snow that lands on it. On a mountain roof that is a height question as much as a clearance question, and drifting snow against a low termination is the failure that shows up in the first storm of the year.
Combustion air is the other half. A closet packed with stored goods or a room sealed against winter turns a working burner into one that soots its flue, and the symptom appears weeks later as a smell or a flame that will not hold.
Connections, commissioning and the record
On gas, the connector, sediment trap and shutoff are renewed when they are older than the tank. An electric unit needs its circuit and breaker verified against the nameplate rather than inherited from the old tank.
Strapping is required either way, and a unit on a platform is tied to the framing rather than to the platform alone. Once filled and purged, the unit is lit and cycled so the relief valve and expansion tank are seen working. The old tank leaves; the model, capacity, date and permit record stay with the owner.
Replacing an existing unit is on the replacement page; a property with several buildings or a camp use belongs with commercial service.