Most installation decisions here are made by the property rather than the product. A canyon lot at 3,389 feet has a frost line, a slope, a forest edge and a service connection, and a heater that ignores any of them will be back on the list within a year.
Place it where it can stay warm
The first question is whether the unit can live inside the conditioned envelope or in a space that stays above freezing. A garage, a utility closet or a crawl-space-adjacent alcove is preferable to an unheated outbuilding, and an exterior wall in a canyon is the worst option.
Where an outbuilding is the only sensible location, the installation has to carry the protection: insulated runs, isolation valves so the building can be drained when it is not in use, and a heat source that keeps the space above freezing or a unit designed for the exposure.
The meter is a boundary and a closure
On the mutual, the meter is where the company's responsibility ends and the property's begins. It is also a closure: a service connection with backflow protection behaves like a closed system, so heated water needs somewhere to expand.
That means an expansion tank on the cold side, sized to the system, whether or not the property has ever had one. The repair page explains what happens when it is missing, which is the single most common misdiagnosed fault on this kind of plumbing.
Size for the inlet, not the brochure
Incoming water in January is close to freezing in a canyon that has been below zero overnight, and a heater's usable output falls as the temperature lift grows. A storage tank recovers more slowly; a tankless unit delivers less flow at the same setting.
Both are sized from the coldest inlet the property sees and the fixtures that run together. A unit chosen on a summer measurement will feel adequate for eight months and disappointing for four.
Vent clearances at the forest edge
The manufacturer sets the clearances, and the site sets the geometry. On a lot with growth close to the building, the termination can sit under vegetation that drops debris into the screen, and a blocked screen produces the same symptom as a failed component.
The vent route also has to be decided before the unit is ordered, because changing it later changes the scope the county reviews. Where the unit is in a closet, combustion air is designed rather than borrowed from a gap under a door.
The county permit
The property is county territory rather than city, so the permit comes from Los Angeles County Public Works, Building and Safety Division, with the application and the inspection on EPIC-LA. A like-for-like swap is a narrower scope than a relocation or a vent change, and the county decides which applies.
Delivery on a slope
Units arrive from Lancaster or Palmdale. Confirm where a vehicle can stop, how far the unit has to be carried and whether steps, a retaining wall or a narrow path is involved. On a sloped lot that planning is half the day.
Commission and protect
Fill, purge, check every joint, confirm the relief discharge route and verify draft. Then insulate the exposed runs, label the isolation valves and leave the water test and the model details with the equipment.
Freeze protection is part of commissioning here, not an optional extra. The maintenance page carries the routine that keeps it working through the winter.