Emergencies here have a different first question from a city address. Not "where is the meter" but "what supplies this house," because the answers differ: a well with a pressure tank, possibly a propane tank in the yard, and a heater with its own valve in between.
The sequence for water
- Close the heater's inlet valve. It is the closest shutoff to the leak and the fastest.
- If it will not close, or the leak is below it, go to the pressure tank and close the valve feeding the house.
- If the leak continues, cut the pump at its breaker, usually in a subpanel near the tank or the pump house.
Cutting the pump protects the well from running dry through a burst line and stops the system refilling the house while the leak is being dealt with. It also tells you something useful: if the pump starts when nothing in the house is open, water is escaping somewhere.
The sequence for heat
Gas, piped: close the appliance valve on the supply line to the unit. The meter stays as it is unless there is a smell of gas, in which case the meter valve closes and the utility is called.
Gas, propane: close the valve on the tank. The regulator and pigtail between tank and house hold pressure, so the line is treated as live and the work waits until it is isolated properly. This is the local difference most worth knowing before an emergency rather than during one.
Electric: switch the circuit off at the panel. A drained tank with an energised element fails quickly, so the power goes off before the water is investigated further.
What not to do
Do not relight a unit that has been under water or whose burner compartment has been wet. Do not tape a leaking tank seam. Do not open a relief valve and leave it open as a way to stop a drip, because it will not reseat reliably afterwards and it is not a repair.
Do not assume the smell of gas is the heater. On a propane property the regulator, the pigtail connection and the tank valve are all part of the same system, and the leak can sit outside the building.
After the water stops
The assessment is straightforward once the system is quiet: is the tank shell breached, or is the leak at a fitting, the relief valve or a connection? A shell leak ends the unit, and the replacement page covers the order and the permit. A fitting or valve leak is a repair.
Where the water has spread, the heater is not the only casualty. A wet electrical panel, a soaked wall cavity or a flooded outbuilding changes the order of work, and drying comes before any decision about equipment.
Why the elevation matters
An emergency in January at 3,061 feet has a second hazard: anything wet freezes. Exposed pipe, a condensate line and a floor drain can all ice up overnight, and an outbuilding that flooded in the evening can have split pipe by morning. Isolating and draining the affected run is part of finishing the job, not a courtesy.
Reaching the property
Hi Vista has no supply yard and the trade comes from Lancaster or Palmdale, so the useful information at the phone stage is the address, the access, whether the gate is locked and where the unit sits. That is what turns a first visit from a survey into a repair. The hub page covers how the community's water and gas systems shape the work.