An emergency on a Del Sur parcel is usually two emergencies wearing one coat: water where it should not be, and heat still being applied to it. The order of the shutdown decides how much damage happens between the two.
The first minute
Stop the water at the heater. That valve is closest to the leak and the fastest to close. If it is seized, or the leak is below it, go to the pressure tank and shut the house side there. If the water keeps coming, the pump's breaker is the last stop, and on a well property it is often the only one that truly ends the flow.
Then stop the heat. A gas unit leaking from its tank near the burner has water and flame in the same compartment, and the gas goes off before anyone inspects anything.
Find the fuel shutoff
Where gas arrives in a pipe, the appliance valve beside the unit is enough, and the meter stays as it is unless someone smells gas inside the building. Where the fuel arrives by truck instead, the stop is a valve wheel on the tank in the yard, and closing it leaves the regulator and the flexible pigtail still holding pressure: those stay live until they are isolated and tested.
Electricity is the third case and the least forgiving. A tank that has emptied with the circuit still on will destroy its element, so the breaker goes first whenever there is any doubt about water level.
Practices that make it worse
Three habits turn a bad afternoon into a worse one. Relighting a wet burner assembly, wrapping a weeping seam in tape and leaving a relief valve held open all share the same flaw: each hides a cause that is still there. A gas smell is the fourth, and it deserves a different response altogether, because on a propane parcel the source may be the tank valve or the regulator rather than anything inside the wall, and a search through the building is not the right first move.
Scald and shock
Hot water at the tap can be dangerously hot if a thermostat has failed, and a tank that has been drained and refilled can deliver a slug of very hot water before it mixes. Run the tap to a safe temperature before anyone uses it, and keep children out of the bathroom until it is confirmed.
Water near a panel, a switch or an exposed connection is an electrical hazard. Kill the circuit before touching anything wet near wiring, and do not stand in water to reach a breaker.
No hot water, nothing leaking
Not every urgent call is a flood. A unit with no hot water and no water on the floor is usually one of four things: the gas is off or the pilot will not hold, the breaker has tripped, a limit or thermostat has failed, or the tank is empty because something upstream stopped filling it. That last one is worth ruling out first, because running an electric element dry turns a cheap fault into a replacement.
What the parcel changes
A heater in an outbuilding serving a workshop is a different emergency from one in a hallway: the shutoffs may be in the pump house rather than the building, the panel may be on an exterior wall, and the water may have been running for hours before anyone walked past. Knowing where the subpanel is before something fails is the single most useful piece of preparation on a parcel like this.
What the visit needs from you
The parcel rather than the mailing city, because Del Sur addresses read Lancaster and the work is county territory. Beyond that: the fuel type, whether the property is on a well and where the pump control sits, whether there is a gate, and what the water is doing now.
That information turns a first visit from a survey into a repair, which matters on a community where units and fittings come from Lancaster or Palmdale.
Once the flow has stopped
With the system quiet, the fault separates quickly into two kinds: a tank whose shell has failed, which ends in replacement, or a component that gave way, which is repairable. The first is the replacement page; the second is a repair. If the water travelled into a wall, a ceiling or an outbuilding, drying outranks any equipment decision, and the hub page explains how the well and the gas supply are arranged here.